Worcester Bosch Fault Code A1

Welcome to the fault-codes section of this site. The following table or page contains the information required to help repair and diagnose the fault codes being shown on the boiler display. You may be guided through the fault finding sequence or steps, for rectifying your boiler with this fault code. Suggested repair solutions may be provided by a link to a repair page. NB Some fault codes are only applicable to a specific range of boilers only.

A1 and fault indicator LED are flashing – Controlled characteristic pump has run dry

StepCheckAction
1.System pressure below 1.2 baryes▶ Power OFF the appliance
▶ Check appliance and system for water leaks and repair as necessary.
▶ Fill system, bleed and re-pressurise
(see Installation Instructions).
▶ Turn ON appliance
A1? go to step 2
no:go to step 2
2.Pump seized or sticking?yesFree/release pump
no:go to step 3
3.Audible bearing damage on pumpyes:▶ Power OFF the appliance
▶ Disconnect the boiler electrical connection.
▶ Drain appliance.
▶ Change the pump (see Installation Instructions).
▶ Fill system, bleed and repressurise
(see Installation Instructions).
▶ Reconnect the boiler electrical connection.
▶ Turn ON the appliance.
no:go to step 4
4.Activate venting sequenceyes▶ Select in the first service level, service function 2.C (Air Purge mode - see page X).
▶ Select the value 1 and store.
▶ Exit the service function.
▶ The boiler vents for eight minutes.
▶ Vent radiators manually.

Information is guidance only; repairs require qualified professionals. Affiliate links may earn us commissions at no extra cost. Do your own due diligence; we accept no liability.